Nominal voltage/frequency range can vary depending on local requirements.
Refer to local requirements for exact number of microinverters per branch.
Monitoring System.
Model number | M1600-2T | M1800-2T | M2000-2T |
---|---|---|---|
Commonly used module power (W) | 320 to 540+ | 360 to 600+ | 400 to 670+ |
Maximum input voltage (V) | 65 | ||
MPPT voltage range (V) | 16-60 | ||
Start-up voltage(V) | 22 | ||
Maximum input current (A) | 4x14 | 4x15 | 4x16 |
Maximum input short circuit current (A) | 4x25 | ||
Number of MPPT | 2 | ||
Number of inputs per PPT | 1 |
output Data(AC) | |||||||||
---|---|---|---|---|---|---|---|---|---|
Rated output power (VA) | 1600 | 1800 | 2000 | ||||||
Rated output current(A) | 7.27 | 6.96 | 6.67 | 8.18 | 7.83 | 7.5 | 9.09 | 8.7 | 8.33 |
Nominal output voltage/range(V) | 220/180-275 | 230/180-275 | 240/180-275 | 220/180-275 | 230/180-275 | 240/180-275 | 220/180-275 | 230/180-275 | 240/180-275 |
NNominal frequency/range (Hz) | 50/45-55 or 60/55-65 | ||||||||
Total harmonic distortion | >0.99 default | ||||||||
Power factor (adjustable) | <3% | ||||||||
Maximum units per 2.5 mmz branch" | 3 | 3 | 2 | ||||||
Maximum units per 4 mm2 branch" | 4 | 4 | 3 | ||||||
Maximum units per 6 mm2 branch" | 5 | 5 | 4 |
Efficiency | |||
---|---|---|---|
CEC peak efficiency | 96.7% | 96.50% | 96.50% |
Nominal MPPT efficiency | 99.80% | ||
Night power consumption (mW) | <50 |
Mechanical Data | |
---|---|
Ambient temperature range (°C) | -40 to +65 |
Dimensions (W x H x D [mm]) | 331 x 218 x 40.6 |
Weight(kg) | 5.56 |
Enclosure rating | Outdoor-IP67(NEMA 6) |
Cooling | Natural convection-No fans |
Features | |
---|---|
Communication | Built-in WiFi module |
Type of isolation | Galvanically lsolated HF Transformer |
Monitoring | Cloud |
Compliance |
EN 50549-1:2019,VDE-AR-N 4105: 2018,UL1741,IEC/EN 62109-1/-2.EC/EN 61000-6-1/-2/-3/-4. IEC/EN 61000-3-2/-3IEC 61727JEC 62116JEC61683.EC60068-2-1/-2/-14/-30 |
Product advantages encompass more efficient, long life, easy to install and safer.
Micro solar inverter is widely used on balcony power plants, mini-PV systems, plug-in solar systems or roof systems in line with the grid and feeds it directly into the home network.
Find answers to common questions about solar energy equipment
selection, maintenance, and usage.
This is just placeholder text. Don’t be alarmed; this is just here to fill up space since your finalized copy isn’t ready yet.
Contact Us to Get personalized assistance and discover how our solutions can meet your specific needs and exceed your expectations.
Contact us to explore tailored product options designed to meet your specific needs and requirements.
Reach out to us for prompt and attentive service that addresses your inquiries and support needs effectively.
Contact us to discover competitive pricing that offers value compared to current market standards.
Contact us for efficient logistics solutions that ensure timely delivery of your orders.